Rib fixation plate
Keywords:
Classification:
Product Advantages
● Minimally invasive implantation, specialized clamps for different parts, easy operation.
● Made of pure titanium, lightweight (only 2 grams per piece), good biocompatibility, free of iron ions, minimal CT artifacts post-surgery, no need for removal after surgery. Flexible fixation without compressing intercostal nerves.
Technical Parameters
Model | Specification (L×W) | Model | Specification (L×W) |
GCRP-01W | 30×11 | GCRP-01W | 30×13 |
GCRP-01W | 30×15 | GCRP-01W | 30×17 |
GCRP-01W | 30×19 | GCRP-01W | 35×11 |
GCRP-01W | 35×13 | GCRP-01W | 35×15 |
GCRP-01W | 35×17 | GCRP-01W | 35×19 |
GCRP-02W | 30×15 | GCRP-02W | 30×17 |
GCRP-03W | 30×15 | GCRP-03W | 30×17 |
GCRP-02W | 30×19 | GCRP-02W | 35×11 |
GCRP-03W | 30×19 | GCRP-03W | 35×11 |
GCRP-02W | 35×13 | GCRP-02W | 35×15 |
GCRP-03W | 35×13 | GCRP-03W | 35×15 |
GCRP-02W | 35×17 | GCRP-02W | 35×19 |
GCRP-03W | 35×17 | GCRP-03W | 35×19 |
GCRP-02W | 40×11 | GCRP-02W | 40×13 |
GCRP-03W | 40×11 | GCRP-03W | 40×13 |
GCRP-02W | 40×15 | GCRP-02W | 40×17 |
GCRP-03W | 40×15 | GCRP-03W | 40×17 |
GCRP-02W | 40×19 | GCRP-02W | 45×11 |
GCRP-03W | 40×19 | GCRP-03W | 45×11 |
GCRP-02W | 45×13 | GCRP-02W | 45×15 |
GCRP-03W | 45×13 | GCRP-03W | 45×15 |
GCRP-02W | 45×17 | GCRP-02W | 45×19 |
GCRP-03W | 45×17 | GCRP-03W | 45×19 |
GCRP-02W | 50×11 | GCRP-02W | 50×13 |
GCRP-02W | 50×11 | GCRP-03W | 50×13 |
GCRP-02W | 50×15 | GCRP-02W | 50×17 |
GCRP-03W | 50×15 | GCRP-03W | 50×17 |
GCRP-02W | 50×19 | GCRP-02W | 55×11 |
GCRP-03W | 50×19 | GCRP-03W | 55×11 |
GCRP-02W | 55×13 | GCRP-02W | 55×15 |
GCRP-03W | 55×13 | GCRP-03W | 55×15 |
GCRP-02W | 55×17 | GCRP-02W | 55×19 |
GCRP-03W | 55×17 | GCRP-03W | 55×19 |
Main Structural Components
The rib fixation plate is made of pure titanium (TA2G) material that meets the requirements of GB/T 13810-2017. Its chemical composition and microstructure comply with GB/T 13810-2017. The product surface is treated with black-gray anodizing. The product is available in both non-sterile and sterile forms, with sterile products sterilized by irradiation and a shelf life of 5 years.
Scope of Application
The rib fixation plate is suitable for internal fixation of rib fractures.